Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
PLoS One ; 16(1): e0245305, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33449952

RESUMO

PURPOSE: To evaluate the performance of eleven Knowledge-Based (KB) models for planning optimization (RapidPlantm (RP), Varian) of Volumetric Modulated Arc Therapy (VMAT) applied to whole breast comprehensive of nodal stations, internal mammary and/or supraclavicular regions. METHODS AND MATERIALS: Six RP models have been generated and trained based on 120 VMAT plans data set with different criteria. Two extra-structures were delineated: a PTV for the optimization and a ring structure. Five more models, twins of the previous models, have been created without the need of these structures. RESULTS: All models were successfully validated on an independent cohort of 40 patients, 30 from the same institute that provided the training patients and 10 from an additional institute, with the resulting plans being of equal or better quality compared with the clinical plans. The internal validation shows that the models reduce the heart maximum dose of about 2 Gy, the mean dose of about 1 Gy and the V20Gy of 1.5 Gy on average. Model R and L together with model B without optimization structures ensured the best outcomes in the 20% of the values compared to other models. The external validation observed an average improvement of at least 16% for the V5Gy of lungs in RP plans. The mean heart dose and for the V20Gy for lung IPSI were almost halved. The models reduce the maximum dose for the spinal canal of more than 2 Gy on average. CONCLUSIONS: All KB models allow a homogeneous plan quality and some dosimetric gains, as we saw in both internal and external validation. Sub-KB models, developed by splitting right and left breast cases or including only whole breast with locoregional lymph nodes, have shown good performances, comparable but slightly worse than the general model. Finally, models generated without the optimization structures, performed better than the original ones.


Assuntos
Neoplasias da Mama/radioterapia , Linfonodos/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Feminino , Humanos , Linfonodos/patologia , Glândulas Mamárias Humanas/efeitos da radiação , Mediastino/efeitos da radiação , Órgãos em Risco , Radiação Ionizante , Dosagem Radioterapêutica , Radioterapia Adjuvante , Estudos Retrospectivos
2.
Radiol Med ; 126(3): 421-429, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32833198

RESUMO

PURPOSE: Aim of this study was to develop a generalised radiomics model for predicting pathological complete response after neoadjuvant chemo-radiotherapy in locally advanced rectal cancer patients using pre-CRT T2-weighted images acquired at a 1.5 T and a 3 T scanner. METHODS: In two institutions, 195 patients were scanned: 136 patients were scanned on a 1.5 T MR scanner, 59 patients on a 3 T MR scanner. Gross tumour volumes were delineated on the MR images and 496 radiomic features were extracted, applying the intensity-based (IB) filter. Features were standardised with Z-score normalisation and an initial feature selection was carried out using Wilcoxon-Mann-Whitney test: The most significant features at 1.5 T and 3 T were selected as main features. Several logistic regression models combining the main features with a third one selected by those resulting significant were elaborated and evaluated in terms of area under curve (AUC). A tenfold cross-validation was repeated 300 times to evaluate the model robustness. RESULTS: Three features were selected: maximum fractal dimension with IB = 0-50, energy and grey-level non-uniformity calculated on the run-length matrix with IB = 0-50. The AUC of the model applied to the whole dataset after cross-validation was 0.72, while values of 0.70 and 0.83 were obtained when 1.5 T and 3 T patients were considered, respectively. CONCLUSIONS: The model elaborated showed good performance, even when data from patients scanned on 1.5 T and 3 T were merged. This shows that magnetic field intensity variability can be overcome by means of selecting appropriate image features.


Assuntos
Quimiorradioterapia Adjuvante , Imageamento por Ressonância Magnética/métodos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Área Sob a Curva , Feminino , Fractais , Humanos , Modelos Logísticos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Neoplasias Retais/patologia , Estudos Retrospectivos , Estatísticas não Paramétricas , Resultado do Tratamento , Carga Tumoral
3.
J Appl Clin Med Phys ; 21(9): 244-251, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32841500

RESUMO

INTRODUCTION: Aim of this study is to dosimetrically characterize a new inorganic scintillator designed for magnetic resonance-guided radiotherapy (MRgRT) in the presence of 0.35 tesla magnetic field (B). METHODS: The detector was characterized in terms of signal to noise ratio (SNR), reproducibility, dose linearity, angular response, and dependence by energy, field size, and B orientation using a 6 MV magnetic resonance (MR)-Linac and a water tank. Field size dependence was investigated by measuring the output factor (OF) at 1.5 cm. The results were compared with those measured using other detectors (ion chamber and synthetic diamond) and those calculated using a Monte Carlo (MC) algorithm. Energy dependence was investigated by acquiring a percentage depth dose (PDD) curve at two field sizes (3.32 × 3.32 and 9.96 × 9.96 cm2 ) and repeating the OF measurements at 5 and 10 cm depths. RESULTS: The mean SNR was 116.3 ± 0.6. Detector repeatability was within 1%, angular dependence was <2% and its response variation based on the orientation with respect to the B lines was <1%. The detector has a temporal resolution of 10 Hz and it showed a linear response (R2  = 1) in the dose range investigated. All the OF values measured at 1.5 cm depth using the scintillator are in accordance within 1% with those measured with other detectors and are calculated using the MC algorithm. PDD values are in accordance with MC algorithm only for 3.32 × 3.32 cm2 field. Numerical models can be applied to compensate for energy dependence in case of larger fields. CONCLUSION: The inorganic scintillator in the present form can represent a valuable detector for small-field dosimetry and periodic quality controls at MR-Linacs such as dose stability, OFs, and dose linearity. In particular, the detector can be effectively used for small-field dosimetry at 1.5 cm depth and for PDD measurements if the field dimension of 3.32 × 3.32 cm2 is not exceeded.


Assuntos
Radiometria , Radioterapia Guiada por Imagem , Humanos , Método de Monte Carlo , Aceleradores de Partículas , Reprodutibilidade dos Testes
4.
Int J Radiat Oncol Biol Phys ; 108(5): 1347-1356, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32758641

RESUMO

PURPOSE: Tumor control probability (TCP)-based early regression index (ERITCP) is a radiobiological parameter that showed promising results in predicting pathologic complete response (pCR) on T2-weighted 1.5 T magnetic resonance (MR) images of patients with locally advanced rectal cancer. This study aims to validate the ERITCP in the context of low-tesla MR-guided radiation therapy, using images acquired with different magnetic field strength (0.35 T) and image contrast (T2/T1). Furthermore, the optimal timing for pCR prediction was estimated, calculating the ERI index at different biologically effective dose (BED) levels. METHODS AND MATERIALS: Fifty-two patients with locally advanced rectal cancer treated with neoadjuvant chemoradiation therapy were enrolled in this multi-institutional retrospective study. For each patient, a 0.35 T T2/T1-weighted MR image was acquired during simulation and on each treatment day. Gross tumor volume was contoured according to International Commission on Radiation Units Report 83 guidelines. According to the original definition, ERITCP was calculated considering the residual tumor volume at BED = 25 Gy. ERI was also calculated in correspondence with several BED levels: 13, 21, 32, 40, 46, 54, 59, and 67. The predictive performance of the different ERI indices were evaluated in terms of receiver operating characteristic curve. The robustness of ERITCP with respect to the interobserver variability was also evaluated considering 2 operators and calculating the intraclass correlation index. RESULTS: Fourteen patients showed pCR. ERITCP correctly 47 of 52 cases (accuracy = 90%), showing good results in terms of sensitivity (86%), specificity (92%), negative predictive value (95%), and positive predictive value (80%). The analysis at different BED levels shows that the best predictive performance is obtained when this parameter is calculated at BED = 25 Gy (area under the curve = 0.93). ERITCP results are robust with respect to interobserver variability (intraclass correlation index = 0.99). CONCLUSIONS: This study confirmed the validity and the robustness of ERITCP as a pCR predictor in the context of low-tesla MR-guided radiation therapy and indicate 25 Gy as the best BED level to perform predictions.


Assuntos
Quimiorradioterapia Adjuvante/métodos , Imagem por Ressonância Magnética Intervencionista , Radioterapia Guiada por Imagem/métodos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Área Sob a Curva , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Terapia Neoadjuvante/métodos , Valor Preditivo dos Testes , Probabilidade , Curva ROC , Neoplasias Retais/patologia , Eficiência Biológica Relativa , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
5.
Med Dosim ; 45(4): 352-358, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32565068

RESUMO

We evaluate the role of stereotactic body radiotherapy using volumetric modulated arc therapy (VMAT) technique as an alternative to high-dose rate brachytherapy (HDR-BT) in the treatment of vaginal cuff in postoperative endometrial cancer. CT scans of 8 patients were used in this study. The clinical target volume (CTV) was defined as the 0.5 cm tissue around the applicator (then subtracting the applicator). Total dose was 30Gy delivered in 5 fractions. In HDR-BT, dose was prescribed at a distance of 0.5 cm from the surface applicator. For VMAT irradiation, a planning target volume (PTV) was obtained from CTV by an expansion of 3 mm. Two VMAT plans were generated using a full arc rotation. The first plan was optimized with an anatomy-based optimization module (PO-VMAT) using a 1mm multileaf collimator beam margin to enhance dose heterogeneity and dose fallout outside the target. The second plan was generated with a full-inverse planning module (FI-VMAT). Conformity (CI100, CI50, CI25), gradient (GI) indexes, and integral doses were calculated. To account for various dose heterogeneity distributions we calculated the equivalent uniform dose (EUD) using the Niemerko model. A Kruskal-Wallis analysis of variance followed by Dunn's-type multiple comparisons was performed. Dose distributions were more heterogeneous with HDR-BT: Dmean was 144.2% of prescription dose for CTV in HDR-BT and 118.5 and 108.6% for PTV in PO-VMAT and FI-VMAT, respectively. The mean values of EUD for CTV were 136.9%, 130.0 %, and 111.0% of prescription dose in HDR-BT, PO-VMAT, and FI-VMAT plans, respectively. GI indexes were 2.81, 3.41, and 4.14 for HDR-BT, PO-VMAT, and FI-VMAT, respectively. Near-maximal doses (D0.1cc) for rectum and bladder were significantly higher in HDR-BT plans compared to PO-VMAT and FI-VMAT plans (rectum: 131.2% vs112.8% vs 112.0%, respectively; bladder: 129.2% vs 108.7%, and 109.8%, respectively). PO-VMAT plans were able to mimic the HDR-BT dose distribution, showing a successful capability of highly conformal dose distribution, EUD values similar to HDR-BT, and steep dose-gradient outside PTV, then providing a reasonable alternative to brachytherapy.


Assuntos
Braquiterapia , Radioterapia de Intensidade Modulada , Feminino , Humanos , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
6.
Radiat Oncol ; 15(1): 152, 2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-32532334

RESUMO

BACKGROUND: Internal Target Volume (ITV) is one of the most common strategies to passively manage tumour motion in Radiotherapy (RT). The reliability of this approach is based on the assumption that the tumour motion estimated during pre-treatment 4D Computed Tomography (CT) acquisition is representative of the motion during the whole RT treatment. With the introduction of Magnetic Resonance-guided RT (MRgRT), it has become possible to monitor tumour motion during the treatment and verify this assumption. Aim of this study was to investigate the reliability of the ITV approach with respect to the treatment fraction time (TFT) in abdominal and thoracic lesions. METHODS: A total of 12 thoracic and 15 abdominal lesions was analysed. Before treatment, a 10-phase 4DCT was acquired and ITV margins were estimated considering the envelope of the lesion contoured on the different 4DCT phases. All patients underwent MRgRT treatment in free-breathing, monitoring the tumour position on a sagittal plane with 4 frames per second (sec). ITV margins were projected on the tumour trajectory and the percentage of treatment time in which the tumour was inside the ITV (%TT) was measured to varying of TFT. The ITV approach was considered moderately reliable when %TT ≥ 90% and strongly reliable when %TT ≥ 95%. Additional ITV margins required to achieve %TT ≥ 95% were also calculated. RESULTS: In the analysed cohort of patients, ITV strategy can be considered strongly reliable only for lung lesions with TFT ≤ 7 min (min). The ITV strategy can be considered only moderately reliable for abdominal lesions, and additional margins are required to obtain %TT ≥ 95%. Considering a TFT ≤ 4 min, additional margins of 2 mm in cranio-caudal (CC) and 1 mm in antero-posterior (AP) are suggested for pancreatic lesions, 3 mm in CC and 2 mm in AP for renal and liver ones. CONCLUSIONS: On the basis of the analysed cases, the ITV approach appears to be reliable in the thorax, while it results more challenging in the abdomen, due to the higher uncertainty in ITV definition and to the observed larger intra and inter-fraction motion variability. The addition of extra margins based on the TFT may represent a valid tool to compensate such limitations.


Assuntos
Artefatos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Neoplasias Abdominais/radioterapia , Tomografia Computadorizada Quadridimensional , Humanos , Imageamento por Ressonância Magnética , Movimento (Física) , Estudos Retrospectivos , Neoplasias Torácicas/radioterapia
7.
Radiol Med ; 125(2): 157-164, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31591701

RESUMO

PURPOSE: MR-guided radiotherapy (MRgRT) relies on the daily assignment of a relative electron density (RED) map to allow the fraction specific dose calculation. One approach to assign the RED map consists of segmenting the daily magnetic resonance image into five different density levels and assigning a RED bulk value to each level to generate a synthetic CT (sCT). The aim of this study is to evaluate the dose calculation accuracy of this approach for applications in MRgRT. METHODS: A planning CT (pCT) was acquired for 26 patients with abdominal and pelvic lesions and segmented in five levels similar to an online approach: air, lung, fat, soft tissue and bone. For each patient, the median RED value was calculated for fat, soft tissue and bone. Two sCTs were generated assigning different bulk values to the segmented levels on pCT: The sCTICRU uses the RED values recommended by ICRU46, and the sCTtailor uses the median patient-specific RED values. The same treatment plan was calculated on two the sCTs and the pCT. The dose calculation accuracy was investigated in terms of gamma analysis and dose volume histogram parameters. RESULTS: Good agreement was found between dose calculated on sCTs and pCT (gamma passing rate 1%/1 mm equal to 91.2% ± 6.9% for sCTICRU and 93.7% ± 5.3% b or sCTtailor). The mean difference in estimating V95 (PTV) was equal to 0.2% using sCTtailor and 1.2% using sCTICRU, respect to pCT values CONCLUSIONS: The bulk sCT guarantees a high level of dose calculation accuracy also in presence of magnetic field, making this approach suitable to MRgRT. This accuracy can be improved by using patient-specific RED values.


Assuntos
Abdome/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pelve/diagnóstico por imagem , Radioterapia Guiada por Imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
8.
In Vivo ; 34(1): 381-387, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31882502

RESUMO

AIM: The aim of this study was to detect clinical factors predictive of loss of visual acuity after treatment in order to develop a predictive model to help identify patients at risk of visual loss. PATIENTS AND METHODS: This was a retrospective review of patients who underwent interventional radiotherapy (brachytherapy) with 106Ru plaque for primary uveal melanoma. A predictive nomogram for visual acuity loss at 3 years from treatment was developed. RESULTS: A total of 152 patients were selected for the study. The actuarial probability of conservation of 20/40 vision or better was 0.74 at 1 year, 0.59 at 3 years, and 0.54 at 5 years after treatment. Factors positively correlated with loss of visual acuity included: age at start of treatment (p=0.004) and longitudinal basal diameter (p=0.057), while distance of the posterior margin of the tumor from the foveola was inversely correlated (p=0.0007). CONCLUSION: We identified risk factors affecting visual function and developed a predictive model and decision support tool (AVATAR nomogram).


Assuntos
Braquiterapia/métodos , Neoplasias da Coroide/radioterapia , Melanoma/radioterapia , Nomogramas , Radioisótopos de Rutênio/uso terapêutico , Neoplasias Uveais/radioterapia , Acuidade Visual/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Coroide/patologia , Feminino , Seguimentos , Humanos , Masculino , Melanoma/patologia , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Neoplasias Uveais/patologia , Acuidade Visual/efeitos da radiação , Adulto Jovem
9.
J Appl Clin Med Phys ; 20(9): 20-30, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31444952

RESUMO

PURPOSE: Magnetic resonance-guided adaptive radiotherapy (MRgART) is considered a promising resource for pancreatic cancer, as it allows to online modify the dose distribution according to daily anatomy. This study aims to compare the dosimetric performance of a simplified optimizer implemented on a MR-Linac treatment planning system (TPS) with those obtained using an advanced optimizer implemented on a conventional Linac. METHODS: Twenty patients affected by locally advanced pancreatic cancer (LAPC) were considered. Gross tumor volume (GTV) and surrounding organ at risks (OARs) were contoured on the average 4DCT scan. Planning target volume was generated from GTV by adding an isotropic 3 mm margin and excluding overlap areas with OARs. Treatment plans were generated by using the simple optimizer for the MR-Linac in intensity-modulated radiation therapy (IMRT) and the advanced optimizer for conventional Linac in IMRT and volumetric modulated arc therapy (VMAT) technique. Prescription dose was 40 Gy in five fractions. The dosimetric comparison was performed on target coverage, dosimetric indicators, and low dose diffusion. RESULTS: The simplified optimizer of MR-Linac generated clinically acceptable plans in 80% and optimal plans in 55% of cases. The number of clinically acceptable plans obtained using the advanced optimizer of the conventional Linac with IMRT was the same of MR-Linac, but the percentage of optimal plans was higher (65%). Using the VMAT technique, it is possible to obtain clinically acceptable plan in 95% and optimal plans in 90% of cases. The advanced optimizer combined with VMAT technique ensures higher target dose homogeneity and minor diffusion of low doses, but its actual optimization time is not suitable for MRgART. CONCLUSION: Simplified optimization solutions implemented in the MR-Linac TPS allows to elaborate in most of cases treatment plans dosimetrically comparable with those obtained by using an advanced optimizer. A superior treatment plan quality is possible using the VMAT technique that could represent a breakthrough for the MRgART if the modern advancements will lead to shorter optimization times.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias Pancreáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/normas , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Aceleradores de Partículas/instrumentação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
10.
Radiat Oncol ; 14(1): 71, 2019 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-31036034

RESUMO

BACKGROUND: Different studies have proved in recent years that hypofractionated radiotherapy (RT) improves overall survival of patients affected by locally advanced, unresectable, pancreatic cancer. The clinical management of these patients generally leads to poor results and is considered very challenging, due to different factors, heavily influencing treatment delivery and its outcomes. Firstly, the dose prescribed to the target is limited by the toxicity that the highly radio-sensitive organs at risk (OARs) surrounding the disease can develop. Treatment delivery is also complicated by the significant inter-fractional and intra-fractional variability of therapy volumes, mainly related to the presence of hollow organs and to the breathing cycle. The recent introduction of magnetic resonance guided radiotherapy (MRgRT) systems leads to the opportunity to control most of the aforementioned sources of uncertainty influencing RT treatment workflow in pancreatic cancer. MRgRT offers the possibility to accurately identify radiotherapy volumes, thanks to the high soft-tissue contrast provided by the Magnetic Resonance imaging (MRI), and to monitor the tumour and OARs positions during the treatment fraction using a high-temporal cine MRI. However, the main advantage offered by the MRgRT is the possibility to online adapt the RT treatment plan, changing the dose distribution while the patient is still on couch and successfully addressing most of the sources of variability. SHORT CONCLUSION: Aim of this study is to present and discuss the state of the art, the main pitfalls and the innovative opportunities offered by online adaptive MRgRT in pancreatic cancer treatment.


Assuntos
Imageamento por Ressonância Magnética/métodos , Órgãos em Risco/efeitos da radiação , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/radioterapia , Radioterapia Guiada por Imagem/métodos , Humanos , Prognóstico
11.
J Appl Clin Med Phys ; 20(6): 194-198, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31055870

RESUMO

The case of a 50-year-old man affected by a rhabdomiosarcoma metastatic lesion in the left flank Is reported. The patient was addressed to 50.4 Gy radiotherapy with concomitant chemotherapy in order to locally control the lesion. A Tri-60-Co magnetic resonance hybrid radiotherapy unit was used for treatment delivery and a respiratory gating protocol was applied for the different breathing phases (Free Breathing, Deep Inspiration Breath Hold and Final Expiration Breath Hold). Three intensity modulated radiation therapy (IMRT) plans were calculated and Final Expiration Breath Hold plan was finally selected due to the absence of PTV coverage differences and better organs at risk sparing (i.e. kidneys). This case report suggests that organs at risk avoidance with MRI-guided respiratory-gated Radiotherapy is feasible and particularly advantageous whenever sparing the organs at risk is of utmost dosimetric or clinical importance.


Assuntos
Imageamento por Ressonância Magnética/métodos , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Rabdomiossarcoma/radioterapia , Neoplasias Torácicas/radioterapia , Suspensão da Respiração , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Rabdomiossarcoma/patologia , Neoplasias Torácicas/secundário
12.
J Contemp Brachytherapy ; 11(1): 54-60, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30911311

RESUMO

PURPOSE: To report the results of a patient's tailored therapeutic approach using a second course of interventional radiotherapy (brachytherapy) in patients with locally recurrent uveal melanoma. MATERIAL AND METHODS: Patients who had already undergone ocular brachytherapy treated at our IOC (Interventional Oncology Center) were considered. Five patients who has received a second course of treatment with a plaque after local recurrences were included in our study. Re-irradiation was performed with Ruthenium-106 (prescribed dose to the apex 100 Gy) or with Iodine-125 plaques (prescribed dose to the apex 85 Gy). Moreover, a systematic literature search was conducted through three electronic databases, including Medline/PubMed, Scopus, and Embase. RESULTS: All patients were initially treated with Ruthenium-106 plaque; the re-irradiation was performed with Ruthenium-106 plaque in three cases and with Iodine in two cases. Mean time between the first and the second plaque was 56.8 months (range, 25-93 months). Local tumor control rate was 100%, no patient underwent secondary enucleation owing to re-treatment failure. Distant metastasis occurred in 1 patient after 6 months from re-treatment. After a median follow-up of 44.2 months (range, 26-65 months) from re-treatment, all patients experienced worsening of the visual acuity (median visual acuity was 0.42 at time of recurrence and decline to 0.24 at the most recent follow-up); cataract occurred in two cases, no patient developed scleral necrosis. We considered 2 papers for a systematic review. CONCLUSIONS: In selected cases, especially in presence of marginal local recurrence, a personalized re-treatment strategy with a plaque may offer high probability of tumor control and organ preservation but worsening of visual acuity.

13.
Radiol Med ; 124(2): 145-153, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30374650

RESUMO

The aim of this study was to evaluate the variation of radiomics features, defined as "delta radiomics", in patients undergoing neoadjuvant radiochemotherapy (RCT) for rectal cancer treated with hybrid magnetic resonance (MR)-guided radiotherapy (MRgRT). The delta radiomics features were then correlated with clinical complete response (cCR) outcome, to investigate their predictive power. A total of 16 patients were enrolled, and 5 patients (31%) showed cCR at restaging examinations. T2*/T1 MR images acquired with a hybrid 0.35 T MRgRT unit were considered for this analysis. An imaging acquisition protocol of 6 MR scans per patient was performed: the first MR was acquired at first simulation (t0) and the remaining ones at fractions 5, 10, 15, 20 and 25. Radiomics features were extracted from the gross tumour volume (GTV), and each feature was correlated with the corresponding delivered dose. The variations of each feature during treatment were quantified, and the ratio between the values calculated at different dose levels and the one extracted at t0 was calculated too. The Wilcoxon-Mann-Whitney test was performed to identify the features whose variation can be predictive of cCR, assessed with a MR acquired 6 weeks after RCT and digital examination. The most predictive feature ratios in cCR prediction were the L_least and glnu ones, calculated at the second week of treatment (22 Gy) with a p value = 0.001. Delta radiomics approach showed promising results and the quantitative analysis of images throughout MRgRT treatment can successfully predict cCR offering an innovative personalized medicine approach to rectal cancer treatment.


Assuntos
Adenocarcinoma/radioterapia , Imageamento por Ressonância Magnética/métodos , Medicina de Precisão , Radioterapia Guiada por Imagem/métodos , Neoplasias Retais/radioterapia , Adenocarcinoma/patologia , Idoso , Idoso de 80 Anos ou mais , Biópsia , Quimiorradioterapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias Retais/patologia , Resultado do Tratamento , Carga Tumoral
14.
Phys Med ; 53: 80-85, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30241758

RESUMO

PURPOSE: Aim of this study is to experimental evaluate the impact of a 0.35 T transverse magnetic field on dose distribution in presence of tissue-air and tissue-lung interfaces. METHODS: The investigation was carried out using MRIdian (ViewRay, Cleveland, Ohio) and it consisted of comparing experimental measurements performed by Gafchromic EBT3 film dosimetry, to Montecarlo simulations, carried out in the presence and, as well as, the absence of the magnetic field. A preliminary dose calibration was planned on MRIdian, arranging 3 × 3 cm2 film pieces in a water slab phantom and exposing them at different beam-on times, in a dose range equal to 0.1-12.1 Gy. All experimental measurements were then carried out using the calibrated films and delivering one single beam orthogonally to three different phantoms: without inhomogeneity, with an air gap and with a lung inhomogeneity. The dose distributions measured by EBT3 films in presence of magnetic field were compared to those calculated in the presence and, as well as, the absence of the magnetic field, in terms of gamma analysis. A quantification of electron return effect (ERE) was also performed. RESULTS: All the tested plans considering the magnetic field show a gamma-passing rate higher than 98% for 3%/3 mm gamma analysis. In presence of tissue-air interface, the electron return effect causes an over-dosage of +31.9% at the first interface and an under-dosage of -33% at the second interface. The dosimetric variations in presence of tissue-lung interface results to be smaller (+0.8% first interface, -1.3% second interface). CONCLUSION: The impact of 0.35 T magnetic field is not negligible and it can be effectively modelled by the Montecarlo dose calculation platform available in the MRIdian TPS.


Assuntos
Campos Magnéticos , Doses de Radiação , Radioterapia Guiada por Imagem , Calibragem , Dosagem Radioterapêutica
15.
Radiother Oncol ; 129(3): 456-462, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30144955

RESUMO

INTRODUCTION: Aim of this study was to investigate the ability of pre-treatment four dimensional computed tomography (4DCT) to capture respiratory-motion observed in thoracic and abdominal lesions during treatment. Treatment motion was acquired using full-treatment cine-MR acquisitions. Results of this analysis were compared to the ability of 30 seconds (s) cine Magnetic Resonance (MR) to estimate the same parameters. METHODS: A 4DCT and 30 s cine-MR (ViewRay, USA) were acquired on the simulation day for 7 thoracic and 13 abdominal lesions. Mean amplitude, intra- and inter-fraction amplitude variability, and baseline drift were extracted from the full treatment data acquired by 2D cine-MR, and correlated to the motion on pre-treatment 30 s cine-MR and 4DCT. Using the full treatment data, safety margins on the ITV, necessary to account for all motion variability from 4DCT observed during treatment, were calculated. Mean treatment amplitudes were 2 ±â€¯1 mm and 5 ±â€¯3 mm in the anteroposterior (AP) and craniocaudal (CC) direction, respectively. Differences between mean amplitude during treatment and amplitude on 4DCT or during 30 s cine-MR were not significant, but 30 s cine-MR was more accurate than 4DCT. Intra-fraction amplitude variability was positively correlated with both 30 s cine-MR and 4DCT amplitude. Inter-fraction amplitude variability was minimal. RESULTS: Mean baseline drift over all fractions and patients equalled 1 ±â€¯1 mm in both CC and AP direction, but drifts per fraction up to 16 mm (CC) and 12 mm (AP) were observed. Margins necessary on the ITV ranged from 0 to 8 mm in CC and 0 to 5 mm in AP direction. Neither amplitude on 4DCT nor during 30 s cine MR is correlated to the magnitude of drift or the necessary margins in both directions. CONCLUSION: Lesions moving with small amplitude show limited amplitude variability throughout treatment, making passive motion management strategies seem adequate. However, other variations such as baseline drifts and shifts still cause significant geometrical uncertainty, favouring real-time monitoring and an active approach for all lesions influenced by respiratory motion.


Assuntos
Neoplasias Abdominais/radioterapia , Neoplasias Torácicas/radioterapia , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Neoplasias Renais/radioterapia , Neoplasias Hepáticas/radioterapia , Neoplasias Pulmonares/radioterapia , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Movimento (Física) , Movimento/fisiologia , Neoplasias Pancreáticas/radioterapia , Posicionamento do Paciente , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Respiração
16.
Cureus ; 10(3): e2292, 2018 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-29750133

RESUMO

The case of a 73-year-old woman affected by anal canal cancer with concomitant liver metastases is presented here. The patient was addressed to stereotactic body radiotherapy (SBRT) on two hepatic secondary lesions after the first radiochemotherapy treatment of the primary tumor. A Tri-60-Co magnetic resonance hybrid radiotherapy unit was used for SBRT treatment delivery. Both liver lesions were not clearly visible on the setup magnetic resonance imaging (MRI) due to their limited dimensions (maximum diameter 13 mm); however, the presence of two cysts adjacent to the metastases allowed the use of an indirect target gating approach. Treatment was delivered in deep inspiration breath-hold conditions using the visual feedback technique for breathing control optimization. Post radiotherapy imaging assessed the complete response.

17.
Artigo em Inglês | MEDLINE | ID: mdl-32095572

RESUMO

INTRODUCTION: Aim of this paper is to investigate the plan quality of a tri-Co-60 MRI-Hybrid system for intensity-modulated radiation therapy (IMRT) in patients affected by locally advanced rectal cancer (LARC) undergoing neo-adjuvant radiotherapy. MATERIALS AND METHODS: Ten consecutive LARC patients were selected. Tri-Co-60 step and shoot IMRT plans were generated simulating the presence of the magnetic field (Bon) or not (Boff) with the dedicated treatment planning system (TPS).The total planned dose was 45 Gy in 25 fractions to the mesorectum and the pelvic nodes (planning target volume 2, PTV2) and 55 Gy to the tumor and correspondent mesorectum (PTV1) through simultaneous integrated boost (SIB). Tri-Co-60 IMRT plans were compared with Volumetric Modulated Arc Therapy (VMAT) and IMRT plans for Linear Accelerator (Linac). RESULTS: Bon and Boff tri-Co-60 IMRT plans showed no relevant differences. Mean values of PTV1 and PTV2 receiving at least 95% of the Dp (V95%) were higher than 95% in all treatment plans. All plans met the V105% constraint for the PTV1. Mean values of V105% for the PTV2 were 14.8, 5.0, and 7.3% respectively for tri-Co-60, VMAT and IMRT. Mean Wu's HI values were similar in all plans (7.4-7.8%). All plans met the V45Gy constraint for small bowel, but mean V45Gy value was higher with tri-Co-60.Bladder irradiation was comparable and always lower than the chosen D max 65 Gy constraint.Mean values of V5Gy and V20Gy to the body and median skin doses were higher with tri-Co-60 plans. DISCUSSION: Treatment plans with Tri-Co-60 step and shoot IMRT met the dose-volume objectives in patients with LARC. Nevertheless, a larger volume of normal tissue received low-moderate doses when compared with Linac based VMAT and IMRT.

18.
Brachytherapy ; 17(2): 432-438, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29275868

RESUMO

PURPOSE: To investigate how treatment complications are related to dosimetric parameters after ruthenium-106 brachytherapy for uveal melanoma, in a large, clinically homogeneous population. METHODS AND MATERIALS: A retrospective review was performed to evaluate patients affected by small and medium size uveal melanoma, treated with ruthenium-106 brachytherapy from December 2006 to December 2014. We excluded tumors with posterior margin within 1 mm from the edge of the optic disc and foveola. Main outcome measures were occurrence and time to radiation-related maculopathy, cataract, and optic neuropathy. Secondary end points included local recurrence and distant metastases. Kaplan-Meier analysis with log-rank test and univariate Cox proportional hazards model at 3 years were performed to identify the covariates affecting the outcome of radiation complications. RESULTS: Two hundred thirty-nine patients, with sufficient data to evaluate the end points, were enrolled. Three years after plaque treatment, radiation maculopathy was found in 61 (25.5%) patients, cataract developed in 10 patients (4.2%) receiving a dose of 27 Gy or higher to the lens, and optic neuropathy was observed in 13 patients (5.4%) with an optic nerve dose exceeding 50 Gy and tumor proximity to optic disc of less than 4 mm. Tumor recurrences and tumor-related metastasis were found respectively in 20 (8.36%) and 14 (5.85%) patients. CONCLUSIONS: Radiation maculopathy occurs within a median time of 31 months in 25% of cases after plaque treatment for uveal melanoma. The most significant risk factors are total dose and distance of tumor margin from the fovea. If the distance is greater than 11.22 mm, no signs of retinal damage are detected.


Assuntos
Braquiterapia/efeitos adversos , Braquiterapia/métodos , Melanoma/radioterapia , Lesões por Radiação/etiologia , Neoplasias Uveais/radioterapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Catarata/etiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Melanoma/patologia , Pessoa de Meia-Idade , Metástase Neoplásica , Recidiva Local de Neoplasia/etiologia , Doenças do Nervo Óptico/etiologia , Modelos de Riscos Proporcionais , Dosagem Radioterapêutica , Doenças Retinianas/etiologia , Estudos Retrospectivos , Fatores de Risco , Radioisótopos de Rutênio , Neoplasias Uveais/patologia , Adulto Jovem
19.
Radiol Med ; 123(4): 286-295, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29230678

RESUMO

The aim of this study was to propose a methodology to investigate the tumour heterogeneity and evaluate its ability to predict pathologically complete response (pCR) after chemo-radiotherapy (CRT) in locally advanced rectal cancer (LARC). This approach consisted in normalising the pixel intensities of the tumour and identifying the different sub-regions using an intensity-based thresholding. The spatial organisation of these subpopulations was quantified using the fractal dimension (FD). This approach was implemented in a radiomic workflow and applied to 198 T2-weighted pre-treatment magnetic resonance (MR) images of LARC patients. Three types of features were extracted from the gross tumour volume (GTV): morphological, statistical and fractal features. Feature selection was performed using the Wilcoxon test and a logistic regression model was calculated to predict the pCR probability after CRT. The model was elaborated considering the patients treated in two institutions: Fondazione Policlinico Universitario "Agostino Gemelli" of Rome (173 cases, training set) and University Medical Centre of Maastricht (25 cases, validation set). The results obtained showed that the fractal parameters of the subpopulations have the highest performance in predicting pCR. The predictive model elaborated had an area under the curve (AUC) equal to 0.77 ± 0.07. The model reliability was confirmed by the validation set (AUC = 0.79 ± 0.09). This study suggests that the fractal analysis can play an important role in radiomics, providing valuable information not only about the GTV structure, but also about its inner subpopulations.


Assuntos
Quimiorradioterapia , Fractais , Imageamento por Ressonância Magnética , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Neoplasias Retais/patologia , Resultado do Tratamento
20.
J Contemp Brachytherapy ; 9(3): 287-295, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28725254

RESUMO

Eye plaque brachytherapy represents a safe and effective therapeutic approach for choroidal melanoma, combining clinical outcomes with an eye and visual preservation. As it represents a complex procedure, a specific quality assurance program is strongly suggested to improve patients and operators safety, and to reduce possible complications linked to surgical procedure and radiation exposure. The aim of this paper is to describe the INTERACTS (Interventional Radiotherapy Active Teaching School) guidelines for quality assurance in choroidal melanoma interventional radiotherapy (brachytherapy) used in our institution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...